Sony ID7000 Data Handling and Storage
Export, data management, and retention policy
Protocol ID: GEN-FLOW-SONY-ID7000-DATA
Version: v1.1
Author: Dillon Corvino
Adapted from: FCCF SOP – Data handling on Sony ID7000 systems fileciteturn1file0
Purpose
This protocol defines mandatory rules and best practices for data export, organization, storage, sharing, and deletion for experiments performed on the Sony Spectral Cell Analyzer ID7000.
The aim is to: - Prevent data loss - Avoid unnecessary duplication of experiments and unmixing matrices - Ensure compliance with FCCF data-retention policies - Reduce congestion on instrument and analysis workstations
Scope
This SOP applies to: - All users of the Sony ID7000 - All instrument PCs and external analysis workstations I and II - All data types generated by the ID7000 software, including: - FCS files - Experiment files (.exdat) - Spectral reference controls
Core rules (read before use)
Failure to follow these rules may result in permanent data loss without notice.
- Export FCS files and experiments immediately after each measurement
- Only store data inside your personal
USERfolder - All data outside the
USERfolder will always be deleted - FCCF performs bi-weekly deletion of:
- All experiments and library controls in the ID7000 software
- Exported experiments and FCS files in
USERfolders older than 6 months
- Users are responsible for early deletion of data no longer needed
Data types and definitions
| Data type | File extension | Description |
|---|---|---|
| FCS files | .fcs |
Event-level flow cytometry data |
| Experiment files | .exdat |
ID7000 experiment definitions, layouts, and settings |
| Reference controls | internal / exported | Spectral reference controls stored in the library or exported |
Exporting FCS files
Using ID7000 Data Agent
- FCS file export is handled by the ID7000 Data Agent
- The Data Agent starts automatically when FCS export is initiated
- The Data Agent icon appears in the task tray
Monitoring export status
- Hover over the ID7000 Data Agent icon to view export progress and status
- A log file documenting the export is written to the output folder
Opening the export folder
- Right-click the ID7000 Data Agent icon
- Select Open Latest Output Folder
- Review exported files and the associated log file
Exporting experiment files (.exdat)
- In the ID7000 software, go to:
- File → Database
- Click Export
- Select the experiment(s) to export
- Click Export
Avoid creating multiple unnecessary unmixing matrices. Multiple matrices generate multiple datasets during FCS export and complicate downstream analysis.
Folder structure and organization
Mandatory folder structure
Create one folder named with your username as a subfolder of USER on the desktop and use only this folder for all exports.
Recommended structure:
USER/
└── <username>/
├── fcs/
├── experiments/
├── reference_controls/
├── projects/
│ ├── project_A/
│ └── project_B/
- You may save the export path in ID7000 Preferences
- Use subfolders to separate:
- FCS files
- Experiment files
- Reference controls
- Project-specific datasets
Data deletion and cleanup
FCCF routinely deletes data without further notice.
You must: - Delete old experiments immediately after analysis on the analysis PC - Delete already analyzed FCS files from all PCs - Delete unnecessary reference controls from the library after export
Additional rules: - Do not make reference controls public (creates duplicates) - Export reference controls before deletion if they are still needed
Use of external analysis workstations
All rules in this SOP apply equally to: - External Analysis Workstation I - External Analysis Workstation II
Recommended workflow to reduce device usage time
To minimize time at the instrument PCs:
- Perform experiment setup on:
- External Analysis Workstation I (older, slower)
- Export the experiment file (
.exdat) - Import the experiment on the instrument PC
- Perform unmixing adjustments on:
- External Analysis Workstation II (newer, faster)
- Export/import
.exdatfiles as required
Long-term storage and transfer
- The recommended storage location is the BTC data server
- Instructions for access:
https://btc-community.uni-bonn.de/your-network/
Transfer data to BTC as soon as possible after export and verify file integrity before deleting local copies.
Buffers Required
Full composition, preparation, storage, and safety information for each buffer lives in its own linked buffer document — only a concise per-buffer summary is reproduced here, generated automatically from that document.
None
Troubleshooting
| Issue | Likely cause | Action |
|---|---|---|
| Missing FCS files | Export not completed | Check Data Agent log and re-export |
| Duplicate datasets | Multiple unmixing matrices | Remove redundant matrices and re-export |
| Data deleted unexpectedly | Stored outside USER folder | Always export into USER/ |
Version history
| Version | Date | Author | Changes |
|---|---|---|---|
| v1.0 | 2025-11-21 | Dillon Corvino | Converted FCCF Sony ID7000 data handling SOP into this repo’s Quarto protocol standard. |
| v1.1 | 2026-09-18 | Dillon Corvino | Replaced # Buffers used (bare library(tidyverse), leaked R package-startup warnings) with an auto-generated # Buffers Required section |